The reliability and construct validity of the functional threshold power test in trained cyclists

Authors

  • Lewis Gough Human Performance and Health group, Centre for Life and Sport Sciences (CLaSS), Birmingham City University, B15 3TN, UK
  • Ben Dobson Sports Nutrition and Performance Research Group, Department of Sport and Physical Activity, Edge Hill University, Ormskirk, United Kingdom
  • Jake Williams Human Performance and Health group, Centre for Life and Sport Sciences (CLaSS), Birmingham City University, B15 3TN, UK
  • Gregory Downes Human Performance and Health group, Centre for Life and Sport Sciences (CLaSS), Birmingham City University, B15 3TN, UK
  • Savannah Sturridge School of Sport and Exercise Sciences, University of Kent, Canterbury, CT2 7PE, UK
  • Ashley Warner Division of Sport and Exercise, School of Health and Life Sciences, University of the West of Scotland, Glasgow, UK
  • Andy Sparks Maurten AB, Gothenburg, Sweden
  • Daniel Brown Centre for Human Performance, Carnegie School of Sport, Leeds Beckett University, Leeds, UK

DOI:

https://doi.org/10.28985/1425.jsc.06

Keywords:

FTP, Cycling Performance, Physiology, Exercise Performance, Wattbike Pro, Time to Exhaustion

Abstract

The functional threshold power (FTP) 20-min test (FTP20) is popular amongst cyclists and coaches due to the theory it can predict the power output that can be sustained for 60-mins. However, little is known in terms of the reliability and validity of this construct, therefore the aim of this study was to assess the reliability of the FTP20 test and the construct validity of this test to predict 60-min power. Twenty-two male trained cyclists (age = 32 ± 10 years, body mass (BM) = 77.2 ± 6.8 kg, maximal oxygen uptake (V̇O2max) = 59.4 ± 5.6 ml.kg-1.min-1 BM) completed five trials consisting of a V̇O2max test, a familiarisation trial of the FTP20, two experimental FTP20 tests, and a time to volitional exhaustion (TLIM) at 95% FTP20. The repeatability for mean power output (MPO) during the FTP20 was excellent (r = 0.94, CI 0.82, 0.98, p<0.001). Mean TLIM (at 95% FTP20) was 42 ± 17-min, with six participants within 10-min of the 60-min suggested threshold. These results suggest that the FTP20 is reliable, however it does not predict 60-min power with a high level of validity. Future research should explore adapting the calculation of FTP whereby the intensity may be lowered (i.e., 80-90% MPO of FTP20), particularly as most participants’ TLIM was far below the suggested 60-min time frame.

Downloads

Download data is not yet available.

Downloads

Published

2025-07-11

How to Cite

Gough, L., Dobson, B., Williams, J., Downes, G., Sturridge, S., Warner, A., Sparks, A., & Brown, D. (2025). The reliability and construct validity of the functional threshold power test in trained cyclists. Journal of Science and Cycling, 14(1), 6. https://doi.org/10.28985/1425.jsc.06

Issue

Section

Original Researches

Most read articles by the same author(s)