Acute Hemodynamic Responses to Three Work-Matched HIIT Training Protocols in Trained Cyclists

Authors

  • Görkem Aybars Balci
  • Hakan Arslan Ege University
  • Burak Alperen Ünsal
  • Ramazan Aydinoğlu
  • Bent Ronny Rønnestad

Keywords:

arterio-venous O2 difference, high-intensity interval training, cardiac output, performance prediction, stroke volume

Abstract

Current literature indicates that studies comprehensively examining acute central and peripheral hemodynamic responses to different high-intensity interval training (HIIT) modalities in trained cyclists remain limited. Therefore, this study aims to compare the acute central cardiac output (Q), stroke volume (SV) and peripheral arteriovenous O2 difference (a−vO2diff) responses elicited by three distinct HIIT models and to determine which modality provides a greater acute stimulus to the respective physiological components. Twelve trained male cyclists (Level 3-4) participated in this study (age: 29.7 ± 5.3 years; maximal oxygen uptake (V̇O2max): 57.8 ± 4.1 mL·min-1·kg-1; body mass: 69.8 ± 6.0 kg). Acute hemodynamic responses were evaluated with three work- and effort-matched HIIT models administered in a randomised order: Long-HIIT (4×3 min work- 3 min recoveries), Short-HIIT (1 series of 15×43.5 sec work - 43.5 sec recovery), and Decreasing Power Output HIIT (DPO-HIIT; 6×114.5 sec work - 114.5 sec recovery). Q, SV, and a−vO2diff were measured using a non-invasive inert gas rebreathing method (N2ORB). Two-way repeated-measures analysis of variance revealed no significant main effect of the protocol for Q (F(2.000, 22.000)=1.966, p=0.178, ηp2=0.152), SV (F(2.000, 22.000)=0.790, p=0.446, ηp2=0.067), heart rate (HR) (F(2.000, 22.000)=0.620, p=0.547, ηp2=0.053), or a−vO2diff (F(2.000, 22.000)=1.586, p=0.227, ηp2=0.126). The Protocol × Time interaction was significant only for HR (F(2.467, 27.132)=4.561, p=0.014, ηp2=0.293). Consequently, while overall systemic stress remains matched, coaches and athletes can utilise these different HIIT structures interchangeably, which may allow for flexibility in endurance training prescription.

Downloads

Download data is not yet available.

References

Buchheit, M., & Laursen, P. B. (2013). High Intensity Interval Training, Solutions to the Programming Puzzle: Part I: Cardiopulmonary Emphasis. Sports Medicine, 43(5), 313–338. https://doi.org/10.1007/s40279-013-0029-x

Caputo, F., & Denadai, B. (2008). The highest intensity and the shortest duration permitting attainment of maximal oxygen uptake during cycling: Effects of different methods and aerobic fitness level. European Journal of Applied Physiology, 103, 47–57. https://doi.org/10.1007/s00421-008-0670-5

Coe, L. N., & Astorino, T. A. (2024). Sex differences in hemodynamic response to high‐intensity interval exercise. Scandinavian Journal of Medicine & Science in Sports, 34(1), e14495. https://doi.org/10.1111/sms.14495

Cohen, J. (1988). Statistical power analysis for the behavioral sciences (2nd ed.). Lawrence Erlbaum Associates. https://doi.org/10.4324/9780203771587

De Pauw, K., Roelands, B., Cheung, S., de Geus, B., Rietjens, G., & Meeusen, R. (2013). Guidelines to Classify Subject Groups in Sport-Science Research. International Journal of Sports Physiology and Performance, 8, 111–122. https://doi.org/10.1123/ijspp.8.2.111

Faricier, R., Paterson, D., & Murias, J. (2025). Physiological Determinants of V̇O 2 max Increase with Endurance Training in a Group Including Older and Young Adults. Medicine & Science in Sports & Exercise, 57. https://doi.org/10.1249/MSS.0000000000003707

Fontana, P., Boutellier, U., & Toigo, M. (2009). Reliability of Measurements with InnocorTMduring Exercise. International Journal of Sports Medicine, 30, 747–753. https://doi.org/10.1055/s-0029-1225340

Jones, A., Vanhatalo, A., Burnley, M., Morton, R., & Poole, D. (2010). Critical Power: Implications for the Determination of VO2max and Exercise Tolerance.

Joyner, M. J., & Dominelli, P. B. (2021). Central cardiovascular system limits to aerobic capacity. Experimental Physiology, 106(12), 2299–2303. https://doi.org/10.1113/EP088187

Richardson, J. T. E. (2011). Eta squared and partial eta squared as measures of effect size in educational research. Educational Research Review, 6(2), 135–147. https://doi.org/10.1016/j.edurev.2010.12.001

Rønnestad, B. R., Hansen, J., Nygaard, H., & Lundby, C. (2020). Superior performance improvements in elite cyclists following short‐interval vs effort‐matched long‐interval training. Scandinavian Journal of Medicine & Science in Sports, 30(5), 849–857. https://doi.org/10.1111/sms.13627

Stanley, J., & Buchheit, M. (2014). Moderate Recovery Unnecessary to Sustain High Stroke Volume during Interval Training. A Brief Report. Journal of sports science & medicine, 13(2), 393–396.

Downloads

Published

2026-10-29

How to Cite

Balci, G. A., Arslan, H., Ünsal, B. A., Aydinoğlu, R., & Rønnestad, B. R. (2026). Acute Hemodynamic Responses to Three Work-Matched HIIT Training Protocols in Trained Cyclists. Journal of Science and Cycling, 15(2), 11. https://www.jsc-journal.com/index.php/JSC/article/view/1147

Most read articles by the same author(s)