
Vol. 7, Issue 1 (2018)
June 2018
Pages 1–23
Sections
Original Researches
-
Agreement between the Stages Cycling and PowerTap Powermeter
Several powermeters for almost every type of bicycle are available. The PowerTap (CycleOps) quantifies cycling power and cadence in the rear wheel hub and has already been validated in previous studies. The Stages Cycling Powermeter (Stages Cycling) is lower-priced and more flexible for usage as it measures in the left crank arm. The aim of this study was to determine the agreement between these two devices.
38 participants performed laboratory tests on a stationary roadbike. Power output and cadence were recorded with PowerTap and Stages simultaneously. Differences in power output and cadence were determined. The agreement between methods was quantified by use of mean differences and limits of agreement.
Stages Powermeter underestimates power output by -1.9±4.0%) in comparison to the PowerTap (limits of agreement: 5.9% to -9.7%). Considering cadence, Stages calculates 0.94± 0.16) revolutions per minute more than the PowerTap (limits of agreement: -0.4 to 2.3 rpm). Mean coefficients of variation for power output (50.1%) and cadence (14.2%) estimate good reliability of Stages compared to PowerTap (50.3% and 14.3%).
Despite a systematic bias, Stages can be considered a suitable alternative to measure power output. However, limitations regarding power output measurement have to be respected, especially when cycling with high intensities.
-
A 1-day maximal lactate steady-state assessment protocol for trained cyclists
The main aim of this study is to assess the validity of a new cycling protocol to estimate the Maximal Lactate Steady-State workload (MLSS) through a one-day incremental protocol (1day_MLSS). Eleven well-trained male cyclists performed 3 to 4 trials of 30-min constant load test (48-72h in between) to determine their respective MLSS workload. Then, on separate days, each cyclist carried out two identical graded exercise tests, comprised of four 10-minute long stages, with the initial load at 63% of their respective maximal aerobic power, 0.2 W·Kg-1 increments, and blood lactate concentration (BLC) determinations each 5 min. The results of the 1day_MLSS tests were analysed through three different constructs: i) BLC difference between 5th and 10th min of each stage (DIF_5to10), ii) BLC difference between the 10th min of two consecutive stages (DIF_10to10), and iii) difference in the mean BLC between the 5th and 10th min of two consecutive stages (DIF_mean). For all constructs, the physiological steady state was determined as the highest workload that could be maintained with a BLC rise lower than 1mmol·L-1. No significant differences were detected between the MLSS workload (247 ± 22W) and any of the 1day_MLSS data analysis (250 ± 24W, 245 ± 23W and 243 ± 21W, respectively; p>0.05). When compared to the MLSS workload, strong ICCs and low bias values were found for these three constructs, especially for the DIF_10to10 workload (r=0.960; Bias=2.2 W). High within-subject reliability data were found for the DIF10_10 construct (ICC=0.846; CV=0.4%; Bias=2.2 ± 6.4W). The 1day_MLSS test and DIF_10to10 data analysis is a valid assessment to predict the MLSS workload in cycling, that considerably reduces the dedicated time, effort and human resources that requires the original test. The validity and reliability values reported in this project are higher than those achieved by other previous MLSS estimation tests.
-
Hayes & Quinn’s TRIMP Concurrent Validity for Cycling
PURPOSE:Quantification models aim to accurately reflect the magnitude of the training stress imposed to the athlete, especially in sports with high training volumes, such as road cycling. The aim of this study was to explore the concurrent validity of a new whole-body bioenergetic TRIMP model (Hayes & Quinn, 2009) correlating the obtained training load scores in road cycling with other commonly used models (the Banister TRIMP, the sRPE model and Training Stress Score (TSS)). METHOD:After three weeks of familiarization with procedures and the performed test to determine VO2max, critical power (Pcrit), anaerobic work capacity (AWC) and Maximal Power Output (Pmax), 12 well-trained road cyclists performed 8 weeks of individual training to record their individual training data (duration, heart rate, power output and rate of perceived effort (RPE)). Different Pearson’s correlation was performed to assess the relationship between models and the changes in fitness. RESULTS: A very large correlation was found between Hayes & Quinn’s TRIMP and RPE session (r = 0.90; p < 0.001) and TSS (r = 0.88; p < 0.01) and a moderate correlation was found with Banister’s TRIMP (r = 0.64; p < 0.05). No significant correlation was found between changes in fitness and Hayes & Quinn’s TRIMP. CONCLUSION:According to these findings, Hayes & Quinn´s TRIMPis a promising mathematical model based on an individual´s bioenergetic profile that could be used to quantify training load in road cycling. This research increases our knowledge about training load models that use power output to measure intensity.
